Its
compact design and combination of set-point sensitivity and narrow or optional
adjustable deadband, offers cost-saving solutions for a variety of
applications. The J6 is ideally suited for a wide range of industrial processes
such as alarm/shutdown and low/high service pressures. OEMs also utilize the J6
in machinery and equipment for threshold protection.
Specifications for
UE Controls J6 Series Pressure SwitchesModel 354-376
Pressure parameters .
354 -Set Point Range: 0 to 50 psi /Deadband: 1.5 to 2.5 psi /Over Range Pressure: 50 psi / Proof pressure: 75 psi
or
356 -Set Point Range: 0 to 100 psi /Deadband: 2 to 4 psi /Over Range Pressure: 100 psi / Proof pressure: 150 psi
or
358 -Set Point Range: 0 to 200 psi /Deadband: 3 to 5 psi /Over Range Pressure: 200 psi / Proof pressure: 250 psi
or
360 -Set Point Range: 0 to 250 psi /Deadband: 3 to 5 psi /Over Range Pressure: 250 psi / Proof pressure: 330 psi
or
362 -Set Point Range: 0 to 350 psi /Deadband: 3 to 8 psi /Over Range Pressure: 350 psi / Proof pressure: 430 psi
or
364-Set Point Range: 0 to 500 psi /Deadband: 3 to 9 psi /Over Range Pressure: 500 psi / Proof pressure: 575 psi
UEONLINE J6 Series Installation and Maintenance Manual.pdf